Articles

Failed extubation in a tertiary-level hospital intensive care unit, Pretoria, South Africa

L G Magose, M Z Koto

Abstract


Background and objective. A prospective cohort study sought to measure the incidence and outcomes of failed extubation in Dr George Mukhari Academic Hospital intensive care unit (ICU), as well as to identify possible factors associated with failed extubation.
Methods. Data were collected over a 6-month period from 1 July 2015 to 31 December 2015. Pre-intubation parameters recorded on the data collection sheet included secretions, Glasgow Coma Scale (GCS), fluid balance, Tobin index, partial pressure of carbon dioxide (pCO2), partial pressure of oxygen (PaO2), comorbidities and weaning method.

Results. A total of 242 patients were enrolled over the 6-month study period. Of the 242 patients, 86 were excluded owing to pre-set exclusion criteria (death before extubation; tracheostomy before extubation; re-intubation >72 hours post extubation). An extubation failure rate of 16.7% (n=26) was observed. The incidence of ventilator-associated pneumonia in the failed extubation group was 19.23%, whereas death was recorded in 42.31% of patients who failed extubation. The average length of ICU stay in the reintubated group was 11.58 days, and 4.04 days for successfully extubated patients. Only low GCS had a statistically significant impact on failed extubation: p=0.0025; odds ratio (OR) for low v. normal 5.13 (95% confidence interval (CI) 1.78 - 14.79). Other predictor variables measured did not reach statistical significance. Weaning method: p=0.3737, OR for No T-piece v. T-piece 1.65 (95% CI 0.547 - 4.976); comorbidities: p=0.5914, OR for two or more comorbidities v. no comorbidities 2.079 (95% CI 0.246 - 17.539), no comorbidities v. single comorbidity 0.802 (95% CI 0.211 - 3.043); fluid balance: p=0.6625, OR for negative v. positive fluid balance 0.571 (95% CI 0.170 - 1.916), OR for neutral v. positive fluid balance <0.001 (95% CI <0.001 - >999.999); pCO2: p=0.7510, OR for high v. normal pCO2 1.344 (95% CI 0.346 - 5.213), OR for low v. normal pCO2 1.515 (95% CI 0.501 - 4.576); PaO2: p=0.4405, OR for high v. normal 1.156 (95% CI 0.382 - 3.494); OR for low v. normal PaO2 2.638 (95% CI 0.553 - 12.587); Tobin index (Fischer’s exact test): p=0.7476.

Conclusion. Low pre-extubation GCS is a predictor of failed extubation.


Authors' affiliations

L G Magose, Department of General Surgery, Sefako Makgatho Health Sciences University, Pretoria, South Africa

M Z Koto, Department of General Surgery, Sefako Makgatho Health Sciences University, Pretoria, South Africa

Full Text

PDF (129KB)

Cite this article

Southern African Journal of Critical Care 2021;37(3):86. DOI:10.7196/SAJCC.2021.v37i3.446

Article History

Date submitted: 2022-01-28
Date published: 2022-01-28

Article Views

Abstract views: 1402
Full text views: 825

Comments on this article

*Read our policy for posting comments here